Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AAPS PharmSciTech ; 22(8): 274, 2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34773199

RESUMO

Freeze-drying is a deceptively complex operation requiring sophisticated design of a robust and efficient process that includes understanding and planning for heterogeneity across the batch and shifts in parameters due to vial or lyophilizer changes. A software tool has been designed to assist in process development and scale-up based on a model that includes consideration of the process heterogeneity. Two drug formulations were used to test the ability of the new tool to develop a freeze-drying cycle and correctly predict product temperatures and drying times. Model inputs were determined experimentally, and the primary drying heterogeneous freeze-drying model was used to design drying cycles that provided data to verify the accuracy of model-predicted product temperature and primary drying time. When model inputs were accurate, model-predicted primary drying times were within 0.1 to 15.9% of experimentally measured values, and product temperature accuracy was between 0.2 and 1.2°C for three vial locations, center, inner edge, and outer edge. However, for some drying cycles, differences in vial heat transfer coefficients due to changes in shelf and product temperature as well as altered product resistance due to product temperature-dependent microcollapse increased inaccuracy (up to 28.6% difference in primary drying time and 5.1°C difference in product temperature). This highlights the need for careful determination of experimental conditions used to calculate model inputs. In future efforts, full characterization of location- and shelf temperature-dependentKv as well as location- and product temperature-dependentRp will enhance the accuracy of the predictions by the model within the user-friendly software.


Assuntos
Dessecação , Laboratórios , Liofilização , Software , Tecnologia Farmacêutica , Temperatura
2.
J Biophotonics ; 14(11): e202100088, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34323374

RESUMO

We report a high light-throughput spectroscopic dosimeter system that is able to noninvasively measure luminescence signals of singlet oxygen (1 O2 ) produced during photodynamic therapy (PDT) using a CW (continuous wave) light source. The system is based on a compact, fiber-coupled, high collection efficiency spectrometer (>50% transmittance) designed to maximize optical throughput but with sufficient spectral resolution (~7 nm). This is adequate to detect 1 O2 phosphorescence in the presence of strong luminescence background in vivo. This system provides simultaneous acquisition of multiple spectral data points, allowing for more accurate determination of luminescence baseline via spectral fitting and thus the extraction of 1 O2 phosphorescence signal based solely on spectroscopic decomposition, without the need for time-gating. Simultaneous collection of photons at different wavelengths improves the quantum efficiency of the system when compared to sequential spectral measurements such as filter-wheel or tunable-filter based systems. A prototype system was tested during in vivo PDT tumor regression experiments using benzoporphyrin derivative (BPD) photosensitizer. It was found that the treatment efficacy (tumor growth inhibition rate) correlated more strongly with 1 O2 phosphorescence than with PS fluorescence. These results indicate that this high photon-collection efficiency spectrometer instrument may offer a viable option for real-time 1 O2 dosimetry during PDT treatment using CW light.


Assuntos
Fotoquimioterapia , Oxigênio Singlete , Luminescência , Fármacos Fotossensibilizantes , Dosímetros de Radiação
3.
J Biomed Opt ; 25(6): 1-13, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32170859

RESUMO

SIGNIFICANCE: Photodynamic therapy (PDT) involves complex light-drug-pathophysiology interactions that can be affected by multiple parameters and often leads to large variations in treatment outcome from patient to patient. Direct PDT dosimetry technologies have been sought to optimize the control variables (e.g., light dose, drug administration, tissue oxygenation, and patient conditioning) for best patient outcomes. In comparison, singlet oxygen (O21) dosimetry has been tested in various forms to provide an accurate and perhaps comprehensive prediction of the treatment efficacy. AIM: We discuss an advanced version of this approach provided by a noninvasive, continuous wave dosimeter that can measure near-infrared spectrally resolved luminescence of both photosensitizer (PS) and O21 generated during PDT cancer treatment. APPROACH: This dosimetry technology uses an amplified, high quantum efficiency InGaAs detector with spectroscopic decomposition during the light treatment to continuously extract the maximum signal of O21 phosphorescence while suppressing the strong PS luminescence background by spectrally fitting the data points across nine narrow band wavelengths. O21 and PS luminescence signals were measured in vivo in FaDu xenograft tumors grown in mice during PDT treatment using Verteporfin as the PS and a continuous laser treatment at 690 nm wavelength. RESULTS: A cohort of 19 mice was used and observations indicate that the tumor growth rate inhibition showed a stronger correlation with O21 than with just the PS signal. CONCLUSIONS: These results suggest that O21 measurement may be a more direct dosimeter of PDT damage, and it has potential value as a definitive diagnostic for PDT treatment, especially with spectral separation of the background luminescence and online estimation of the PS concentration.


Assuntos
Fotoquimioterapia , Fármacos Fotossensibilizantes , Animais , Humanos , Luminescência , Camundongos , Fármacos Fotossensibilizantes/uso terapêutico , Dosímetros de Radiação , Oxigênio Singlete
4.
Simul Healthc ; 5(3): 179-84, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20651481

RESUMO

INTRODUCTION: When navigating a needle from skin to epidural space, a skilled clinician maintains a mental model of the anatomy and uses the various forms of haptic and visual feedback to track the location of the needle tip. Simulating the procedure requires an actuator that can produce the feel of tissue layers even as the needle direction changes from the ideal path. METHODS: A new actuator and algorithm architecture simulate forces associated with passing a needle through varying tissue layers. The actuator uses a set of cables to suspend a needle holder. The cables are wound onto spools controlled by brushless motors. An electromagnetic tracker is used to monitor the position of the needle tip. RESULTS: Novice and expert clinicians simulated epidural insertion with the simulator. Preliminary depth-time curves show that the user responds to changes in tissue properties as the needle is advanced. Some discrepancy in clinician response indicates that the feel of the simulator is sensitive to technique, thus perfect tissue property simulation has not been achieved. CONCLUSIONS: The new simulator is able to approximately reproduce properties of complex multilayer tissue structures, including fine-scale texture. Methods for improving fidelity of the simulation are identified.


Assuntos
Anestesia Epidural/métodos , Instrução por Computador/métodos , Agulhas , Interface Usuário-Computador , Algoritmos , Anestesia Epidural/instrumentação , Simulação por Computador , Desenho de Equipamento , Retroalimentação Sensorial , Humanos , Torque
5.
J Biomed Opt ; 13(3): 034010, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18601555

RESUMO

Photodynamic therapy (PDT) is a promising cancer treatment. PDT uses the affinity of photosensitizers to be selectively retained in malignant tumors. When tumors, pretreated with the photosensitizer, are irradiated with visible light, a photochemical reaction occurs and tumor cells are destroyed. Oxygen molecules in the metastable singlet delta state O2(1Delta) are believed to be the species that destroys cancerous cells during PDT. Monitoring singlet oxygen produced by PDT may lead to more precise and effective PDT treatments. Our approach uses a pulsed diode laser-based monitor with optical fibers and a fast data acquisition system to monitor singlet oxygen during PDT. We present results of in vitro singlet oxygen detection in solutions and in a rat prostate cancer cell line as well as PDT mechanism modeling.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Oximetria/instrumentação , Neoplasias da Próstata/metabolismo , Radiometria/instrumentação , Oxigênio Singlete/análise , Animais , Linhagem Celular Tumoral , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Masculino , Fibras Ópticas , Doses de Radiação , Ratos
6.
J Biomed Opt ; 13(6): 064035, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19123681

RESUMO

Photodynamic therapy (PDT) is a promising cancer treatment that involves optical excitation of photosensitizers that promote oxygen molecules to the metastable O(2)(a(1)Delta) state (singlet oxygen). This species is believed to be responsible for the destruction of cancerous cells during PDT. We describe a fiber optic-coupled, pulsed diode laser-based diagnostic for singlet oxygen. We use both temporal and spectral filtering to enhance the detection of the weak O(2)(a-->X) emission near 1.27 microm. We present data that demonstrate real-time singlet oxygen production in tumor-laden rats with chlorin e6 and 5-aminolevulinic acid-induced protoporphyrin photosensitizers. We also observe a positive correlation between post-PDT treatment regression of the tumors and the relative amount of singlet oxygen measured. These results are promising for the development of the sensor as a real-time dosimeter for PDT.


Assuntos
Lasers , Oximetria/instrumentação , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/tratamento farmacológico , Processamento de Sinais Assistido por Computador/instrumentação , Animais , Linhagem Celular Tumoral , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Masculino , Oximetria/métodos , Fotoquimioterapia , Neoplasias da Próstata/metabolismo , Ratos , Reprodutibilidade dos Testes , Semicondutores , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...